My Crossbar PBX · Volume 6

Troubleshooting

6.1 What This Volume Covers

This is the troubleshooting manual for the crossbar exchange on the back of the panel. Its method is the same as the Strowger side’s (My Strowger PBX, Volume 6): first ask who is affected, then make one call and watch which light was the last to come on. What is different is where faults live. A Strowger switch’s faults are mostly in its stepping mechanism; a crossbar switch has almost no motion, so its faults are mostly in contacts (the crosspoints, the off-normal springs) and in the sequence of the common control.

Everything here is drawn from the circuits of Volume 3, the 755A’s own practices and the Strowger side’s manual, until the exchange is built.

6.2 First: Who Is Affected?

Table 1 — First: Who Is Affected?

ClassWho is affectedWhere the fault must be
1one telephone onlyits telephone, its wiring, its line circuit, or its vertical (hold magnet, crosspoints, off-normal springs)
2calls on one link onlythat link circuit, or its bar (select magnets, fingers, off-normal springs, its two rows of crosspoints)
3everyone, some of the timesomething used part of the time: one link, the link allotter, the register, the trunk
4everyone, all the timethe common control, the fuses X1–X7, the shared supply, ringing or tones

To test one link, busy the others: hold a call up on them, or (as the 755A provided) switch them out. The 755A had link cutout keys CO1–CO3 for exactly this; its link test begins by operating all three and checking that “busy tone is heard” (BSP 550-550-590, §4.01–4.02). A key per link on this exchange makes every link testable on its own.

6.3 Then: Which Light Stopped?

Table 2 — Then: Which Light Stopped?

Last light litWhat did not happenLook at
nothingthe line relay did not operatethe telephone; fuse X3; L through CO’s break springs
OFF-HOOK, but no common control BUSYthe startST and LS wiring; the common control’s start relay; fuse X7
common control BUSY, but no bar lightno select magnetthe link allotter (is any link free?); fuse X1; the select magnet itself
bar light, but no mimic LEDthe hold magnet did not close the crosspointthe bar’s off-normal springs (the common control waits for them); fuse X2; the hold magnet; a bent or stuck finger
mimic LED flashes and goes outthe link’s hold ground did not take overthe link’s B relay; the row’s S lead; the S contact pair at that crosspoint
SEIZED, but no DIAL TONEthe link’s A relay or the DT leadA; the shared dial-tone supply
register shows the wrong digitspulse countingthe dial (test it on the RS 43-114); the register’s slow-release digit timing
register right, but BUSY on an idle linethe busy test saw ground on BYthat vertical’s off-normal springs stuck operated
completing mimic LED never lightscompletionas for the caller’s crosspoint, on the completing row: bar down, then the called vertical
RINGING, but no TALKING on answerring triprelay F; ringing must ride on battery (shared, My Strowger PBX, Volume 4)
TIME-OUT lampa step never reportedwhichever off-normal spring the sequence was waiting for

6.4 Symptoms and Causes

6.4.1 The switch

Table 3 — The switch

SymptomLook at
A bar will not rockIts select magnet, its fuse (X1), the magnet’s armature and return spring
A bar rocks but the crosspoint never makesA finger bent, broken or missing at that crosspoint; the actuating spring; the contact pair itself
A crosspoint makes, but the call is noisy or one-wayOne contact pair of the crosspoint dirty or open: T or R. “Dirty contacts are electrically open contacts” (TB 565)
Two crosspoints close on one verticalTwo select magnets operated at once: the common control’s one-at-a-time chain has failed. The 755A’s call allotter prevented “double connections” this way (BSP 550-550-110, §6.09)
A vertical stays in after the callIts hold magnet still has ground on S: the link has not released, or S is shorted to ground; or the armature is sticking mechanically
A crosspoint opens by itself during a callThe S contact pair at that crosspoint is dirty, so the hold magnet loses its ground

6.4.2 The relay circuits

Table 4 — The relay circuits

SymptomLook at
A line is always busyIts vertical’s off-normal springs stuck operated (BY grounded), or its cut-off relay stuck
Every call takes the same linkThe link allotter is not advancing; the 755A’s allotter rotates “successive links on successive calls” (BSP 550-550-110, §3.02)
Busy tone on lifting the handsetAll links busy or cut out; the link allotter; the link cutout keys left off
The common control hangs until resetA missing off-normal report, caught by the time-out (Volume 4): find which step it stopped on from the lights
Dialling extra pulses or a dropped digit causes a wrong numberThe register’s digit timing; the 755A’s links were tested to make “dialing of preliminary or extra pulses … ineffective” (BSP 550-550-590, §1.03)

6.4.3 The trunk to the Strowger side

Table 5 — The trunk to the Strowger side

SymptomLook at
Dial 9: no Strowger dial toneThe cut-through relay CT; the trunk’s supervisory relay; then line 66 on the Strowger side, as a class 1 fault there (My Strowger PBX, Volume 6)
Strowger dial tone, but 22–55 never ringThe pulses are not reaching the Strowger connector: a series element in the loop (CT not fully operated, a resistor left in by the supervisory relay)
Dialling 66 from the Strowger side rings nothing hereThe ring detector; the trunk circuit’s fuse; the selector switch setting
The trunk stays busy after a callThe supervisory relay holding: the link has not seen the release

6.5 Tools and Routine Tests

  • The bring-up controller (Volume 4) is also the best test set for the switch: it can operate any bar and vertical by hand, and read every off-normal spring.
  • A multimeter across each crosspoint’s contact pairs, with the crosspoint closed by the controller.
  • A hand test set on a line’s terminals, as the 755A’s practices used (“connect the dial hand test set to the T and R terminals associated with an idle key station”, BSP 550-550-590).
  • The link cutout keys, to force calls onto one link.

The 755A’s equipment test list (BSP 550-001-011) scheduled its alarm tests and its link and link-allotter tests. Adapted for a display exchange:

Table 6 — The 755A's equipment test list ([BSP 550-001-011](https://telephones.fubsypoly.com/library/bsp-550-001-011-755a-equipment-test-list-1972/)) scheduled its alarm tests and its link and link-allotter tests. Adapted for a display exchange

WhenTest
Each time it is shownEvery line calls every other; two calls at once; a call each way to the Strowger side
MonthlyWith the cutout keys, each link alone: dial tone, busy tone with the others cut out, a call through it (BSP 550-550-590)
Every two monthsWith the controller: every crosspoint in use makes and breaks on all its pairs; every off-normal spring reports
YearlyClean the switch: dust out the fingers and contacts; burnish only contacts that test dirty

6.6 In the Reference Library

Sources

  • Bell System Practices 550-550-110 (1937), 550-550-590 (1952) and 550-001-011 (1972), for the 755A PBX, Reference Library.
  • Automatic Electric, Technical Bulletin 565 (1961), Reference Library.
  • My Strowger PBX, Volume 6, and My Crossbar PBX, Volumes 3–5, on this site.