My Crossbar PBX · Volume 2

Bill of Materials

2.1 How to Read This List

This is everything the four-telephone crossbar exchange in Volume 1 needs, grouped the way it is built: the switch, the relay circuits, power, ringing and tones, the trunk to the Strowger system, telephones, the display, wiring and mounting, and the tools to bring it up. Nothing is owned yet, so the Have column is empty for now.

Two things make this list different from the Strowger build’s:

  • The switching network is one part. A single crossbar switch does what the Strowger panel’s four two-motion switches do. Most of the work, and most of the part count, is in the relay circuits around it.
  • Much of the common equipment can be shared. The Strowger panel’s 48-volt supply, ringing, interrupters and tones (My Strowger PBX, Volume 4) feed this exchange too: the crossbar system goes on the back of the Strowger panel (decided 26 October 2026), so it shares them (Volume 4).

Relay quantities are estimates until the circuits are drawn in Volume 3. They are worked out from the jobs the 755A’s six circuits did (Bell Laboratories Record, June 1938) and from the relays a Strowger connector uses for the same jobs. They are not copied from a 755A drawing, because none has been found.

2.2 The Crossbar Switch

Table 1 — 1. The Crossbar Switch

#ItemQtyHaveNotes
1.1Crossbar switch, 10 verticals × 5 selecting bars (100 crosspoints)1A Western Electric type-324 100-point switch is about 21 in long, 9 in tall and about 30 lb, “made mostly of steel”, with two magnets per selecting bar and one per vertical: 20 magnets (calling315.com). An Ericsson switch also works (Volume 1). Must be complete: every bar, finger, magnet and contact spring.
1.2A second switch, for spares or later growth0–1The 755A grew to twenty lines by adding a second switch that acted “as a single switch with twenty vertical bars.” A damaged switch is also a source of fingers and springs.
1.3Mounting brackets or a frame for the switch1The switch mounts vertically with its bars horizontal, as in the photos in Volume 1. 30 lb needs a proper bracket, not the panel skin alone.
1.4Terminal strips for the switch’s multiples2–3The verticals (lines) and horizontals (link and trunk ends) each bring out a set of leads; terminate them so the switch can be changed without rewiring.

What to check on a switch before buying (Volume 1): completeness; the magnet voltage (the 755A ran on 18–25 V, the 756A on 48 V, so a switch may have 24 V or 48 V magnets; Bell System Practice 550-550-110, General Description, 755A PBX (1937)); the coil markings or resistances; any maker’s code on the frame, to find its drawing; and the condition of the contact sets at a few crosspoints. How many contact pairs each crosspoint has matters: a talking connection needs at least the two line wires plus one control lead.

Where to look. No working switch was confirmed for sale on 26 October 2026. The listings found were souvenirs, such as a Western Electric 1XB crossbar set in Lucite as a paperweight at an asking price of US$499.95 (eBay, transient). That is an asking price for a display piece, not a guide to what a working switch costs. The places to watch:

  • eBay sold listings for “crossbar switch”, which show what switches actually fetch.
  • The collector forums: Classic Rotary Phones has a Western Electric crossbar switch thread, and the Telephone Collectors International (TCI) community.
  • Telephone museums and their sales of surplus, and the Lancaster and other collector shows listed in the Strowger build’s sourcing notes.

2.3 The Relay Circuits

The 755A ran its switch with six circuits (“the line circuit; the trunk circuit; the link circuit; the common control and cut-off circuit; the common timing, tone, and ringing circuit; and the ‘link-allotter’ circuit”), largely built from Western Electric “U and Y” type relays. The table estimates each one for four lines and two or three links.

Table 2 — 2. The Relay Circuits

#CircuitPerQtyRelays (estimate)Job
2.1Line circuittelephone42 each (line and cut-off), so 8Sees the handset lift, tells the common control, and later operates the line’s hold magnet. The same pair the Strowger panel uses.
2.2Link circuitlink2–3about 8–10 each, so 16–30Everything a Strowger connector’s relays do except stepping: battery feed and supervision, dial-pulse following, busy test, busy tone, ringing, ring trip, ringback, release.
2.3Register, part of each linklink2–3see the table belowRecords the dialled number.
2.4Common control and cut-offexchange1about 4–8Operates the right select magnet, then the right hold magnet, then lets go. Only one select magnet may operate at a time, and it must stay operated until the hold magnet has pulled in (telephonetribute.com, ch. 6, via the sourcing notes).
2.5Link allotterexchange12–3Picks the idle link for the next call.
2.6Trunk circuit, on vertical 9trunk1about 4–6To the Strowger P-A-X, looks like a telephone line: seizes it, passes the dial pulses. Incoming, it detects the P-A-X’s ringing, answers, and asks for a link to one chosen crossbar telephone, set by a selector switch (Volume 3).
2.7Common timing, tone and ringingexchange00Shared with the Strowger panel (section 4).

The register depends on the numbering. The numbers are 61, 62, 63 and 64: two digits, like the Strowger panel’s 22–55, and never clashing with them. So each link’s register must record two digits, which can be counted three ways (the third, single-digit numbers, is shown for comparison):

Table 3 — The register depends on the numbering. The numbers are 61, 62, 63 and 64: two digits, like the Strowger panel's 22–55, and never clashing with them. So each link's register must record two digits, which can be counted three ways (the third, single-digit numbers, is shown for comparison)

RegisterPer linkForAgainst
Relay counting chains, as the 755A’s “pulsing and register relays”about 10–12 relays per digitAll relays, period-correct; the visitor sees each pulse countedThe largest relay count; two digits double it
A small rotary stepping switch per digit1 stepping switch per digit, plus 1–2 relaysFew parts; each pulse visibly steps a wiper, a link back to the Strowger panelNot how Bell did it
Single-digit numbers (1–4, and 9 for the trunk)one digit’s worth of either of the aboveHalves the registerNumbering differs from the Strowger panel’s two digits

Estimated total: with two-digit numbers, about 60–90 relays if the registers are relay counting chains, or about 35–60 if each digit is counted by a small stepping switch. The register choice is now the biggest single lever on the part count.

Which relays. Two routes, which can be mixed:

Table 4 — Which relays. Two routes, which can be mixed

#ItemQtyHaveNotes
2.8Period telephone relays: Western Electric U/Y-type or wire-spring, 48 V coilsper the circuitsCorrect for a Bell crossbar exchange, and they turn up on the collector market (eBay: Western Electric relays, transient). Coil and spring combinations vary: buy against the circuit design, not by the pound.
2.9Modern plug-in relays, 48 V DC coil, four changeover contacts (for example the Omron MY4 family)per the circuitsAbout US$15–19 each from distributors (search snippets, 26 October 2026; confirm the coil voltage on each listing). Easy to source and replace; four changeover contacts are enough for most jobs here.
2.10Sockets for 2.9 (for example Omron PYF14A)one per relayAbout US$3–10 each (search snippets). Lets a relay be swapped in seconds during bring-up.
2.11Relay mounting: rack strips, DIN rail or plates3–6One plate or rail per circuit, labelled, so each circuit can be watched and fault-found on its own.
2.12Spark suppression for every magnet and relay coilper coilThe 1944 Strowger PAX used capacitors with series resistors across its magnet circuits (E-75159). Each select and hold magnet is an inductive load that throws a spike when released.
2.13Link cutout keys, one per link3As on the 755A (CO1–CO3): take a link out of service so calls are forced onto the others, for testing (Volume 6).

2.4 Power

Table 5 — 3. Power

#ItemQtyHaveNotes
3.148 V DC supply, positive side to ground0Shared: the Strowger panel’s supply (a 10.5 A unit, My Strowger PBX, Volume 4); check its steady load with the hold magnets (Volume 4). The 756A ran on 48 V (BLR, December 1957), so a Bell switch is expected to have 48 V magnets, but this must be confirmed on the switch bought.
3.2Fuses for the crossbar exchange7X1–X7 (Volume 4). The Strowger fuse panel’s ten positions are already assigned, so it becomes a 20-position panel, or gains a second panel.

Current. Unlike a Strowger switch, a crossbar switch draws current for the whole call: each held crosspoint needs its vertical’s hold magnet operated (US 3,400,225, via the sourcing notes). Two calls hold four verticals at once, on top of the link relays. The hold-magnet current is not known until a switch is measured, so the supply rating is checked then.

2.5 Ringing and Tones

Table 6 — 4. Ringing and Tones

#ItemQtyHaveNotes
4.1Ringing generator, interrupters, dial and busy tone0Shared with the Strowger panel’s common equipment: the crossbar links take RG, DT and BT from the same leads as the Strowger connectors (My Strowger PBX, Volume 4). The generator must ring up to four bells at once.

2.6 The Trunk to the Strowger System

Table 7 — 5. The Trunk to the Strowger System

#ItemQtyHaveNotes
5.1Trunk circuit relaysin 2.6
5.2A fifth line on the Strowger P-A-X: line and cut-off relays1 setThe trunk is a telephone line to the P-A-X. Its number goes on a free connector bank position (for example 66), with its line equipment beside the other four.
5.3Bank wiring for the new number, on both finders and both connectors1 setThe Strowger panel’s bank map leaves room: every position except the four lines is unwired (My Strowger PBX, Volume 3).
5.4Cable between the two systems1One pair plus a spare, through the panel to line 66’s equipment on the Strowger side.

2.7 Telephones

Table 8 — 6. Telephones

#ItemQtyHaveNotes
6.1Rotary-dial telephones4A Western Electric 500 suits a Bell crossbar exchange. Qualify each one on the Radio Shack 43-114 before it goes on the exchange: dial speed, ringer, transmission.
6.2Line cords and jacks4

2.8 The Display

Table 9 — 7. The Display

#ItemQtyHaveNotes
7.1Clear cover for the switch1So visitors see the bars rock and the verticals snap in without reaching the contacts.
7.2LEDs: a 30-LED crosspoint mimic (lines × link rows), plus lights for the bars, lines, links, trunk and common controlabout 60The mimic LEDs are switched by a spare contact pair at each crosspoint (the 755A’s switch had six pairs per crosspoint; the call uses three), so they need no opto-isolators. The rest watch relays through opto-isolators, as on the Strowger panel (Volume 5).
7.3Opto-isolatorsabout 30The 12 V display supply is shared with the Strowger panel. Nothing in the display touches the talking path.

2.9 Wiring and Mounting

Table 10 — 8. Wiring and Mounting

#ItemQtyHaveNotes
8.1Switchboard cable and hook-up wireas neededAs for the Strowger panel.
8.2Terminal blocks: telephones, trunk, power3
8.3Board for the crossbar system0None: it goes on the back of the Strowger panel, leaving the right-hand third of the back free for text and photographs (Volume 4).
8.4Labels: switch rows and verticals, circuits, fuses1 setYellow labels, matching the Strowger panel.

2.10 Bring-Up and Test

Table 11 — 9. Bring-Up and Test

#ItemQtyHaveNotes
9.1Microcontroller board and 20 magnet drivers (transistor or relay outputs, each with a flyback diode)1 setRoute C in Volume 1: prove the switch’s 20 magnets and 100 crosspoints before any relay circuit is built. Each crosspoint is closed by operating a select magnet, then a hold magnet, then releasing the select magnet (calling315.com).
9.2Continuity tester or multimeter1To check every crosspoint’s contacts close and open.
9.3Contact burnisher, relay adjusting pliers, feeler gauges1 setShared with the Strowger panel’s tool kit.

2.11 Shared with the Strowger Panel

The crossbar system goes on the back of the Strowger panel (decided 26 October 2026). The table shows what that choice shares, beside the alternative it replaced:

Table 12 — The crossbar system goes on the back of the Strowger panel (decided 26 October 2026). The table shows what that choice shares, beside the alternative it replaced

If the crossbar system goes…SharedExtra
on the back of the Strowger panel (chosen)48 V supply, fuse panel, ringing, interrupters, tones, display supply, toolsaccess to both faces; wiring through the panel
on its own board, beside ittools; the trunk cable joins the twoits own 48 V supply, fuses, ringing and tones, display supply

2.12 In the Reference Library

Sources

  • Bell System Practice 550-550-110, General Description, 755A PBX, issue 1 (1937), Reference Library.
  • J. N. Reynolds and C. R. Gray, Bell Laboratories Record, June 1938, Reference Library.
  • O. H. Williford, “A Modern Crossbar PBX”, Bell Laboratories Record, December 1957, Reference Library.
  • Western Electric type-324 switch size, weight, magnets and drive sequence: calling315.com.
  • Driving rules and hold-magnet current: the sourcing notes (02-inputs/research/crossbar_options.md), citing telephonetribute.com and US 3,400,225.
  • Relay and socket prices: distributor search snippets, 26 October 2026; check live before ordering.
  • My Strowger PBX, Volumes 2–4, on this site.