TM 11-2111 Tools, Testing Equipment and Common Supplies, Step-by-Step Dial Central Office Equipment
D E P A R T M E N T OF THE
ARMY TECHNICAL MANUAL
TOOLS
TESTING EQUIPMENT
AND COMMON SUPPLIES
STEP- BY- STEP DIAL
CENTRAL
OFFICE EQUIPMENT
IT-
DEPARTMENT OF THE ARMY
-
MAY 1950
D E P A R T M E N T O F T H E ARLWY T E C H N I C A L M A N U A L
TOOLS
TESTING EQUIPMENT
AND COMMON SUPPLIES
STEP - BY- STEP DIAL
CENTRAL
OFFICE EQUIPMENT
DEPARTMENT OF THE ARMY
Uliited States Gowernrnent Printing Ofice
Washington: 1950
DEPARTMENT OF T H E ARMY
WASHINGTON
25, D. C., 10 M a y 1950
TM 11-2111 is published for the information and guidance of all concerned.
[AG 300.7 (29 Nov 49)]
BY ORDER OF THE SECRETARY
O F THE ARMY:
J. LAWTON COLLINS
Clzief of Staff, United S t a t e s A r h y
EDWARD F. WITSEIJL
Major General, U S A
The A d j u t a f z t General
DISTRIBUTION
:
Tech sv (2) except 11 (50) ; Arm & Sv Bd (1) ; A F F Bd (ea Sv Test Scc) (1); A F F (5) ; OS Maj
Comd (5) ; Base Comd (3) ; MDW (5) ; A (5) ; CHQ (2) ; F C ( 2 ) ; Sch (2) except 11 (10) ; Gen
Dep (2) ; Dep 11 (5) ; Tng Ctr (2) ; P E ( l o ) , OSD (2) ; Lab 11 (2) ; 4th & 5th Ech Maint Shops 11
(2) ; Two ( 2 ) copies to each of the following T/O&E7s: 11-47 ; 11-107 ; 11-127 ; 11-500 GA,GB,GC,
GD,GE,GH ; 11-587 ; 11-592 ; 11-597 ; SPECIAL DISTRIBUTION.
For explanation of distribution formula, see SR 310-90-1.
CONTENTS
Paragraph
.
Page
.
Section I General
Scope ......................................................................................................................................................
Forms and records .......................................................................................................
......................
References ............................................................................................................................................
.
.
I 1 Description and Data of Test Equipment
General ..................................................................................................................................................
Type 1 test desk ..................................................................................................................................
Test sets supplied by the manufacturer .........................................................................................
Other test equipment supplied by the manufacturer ....................................................................
Signal Corps standard test equipment .......................................
; .....................................................
Dial speed and pulse ratio test set ....................................................................................................
Type 31 portable dial speed test set ..................................................................................................
Buzzer test set ......................................................................................................................................
Test stand ..............................................................................................................................................
.
.
CHAPTER 2 OPERATING INSTRUCTIONS AND THEORY OF OPERATION FOR TEST EQUIPMENT
Test handset ........................................................................................................................................
13
Testlamp ..............................................................................................................................................
14
Dial speed and pulse ratio test set ....................................................................................................
15
Type 31 portbble dial speed test set ................................................................................................ 16
Buzzer test set ......................................................................................................................................
17
Teststand ............................................................................................................................................
18
.
.
CHAPTER 3 MAINTENANCE TOOLS AND MATERIALS
Maintenance tools. materials. and supplies ..................................................................................... 19
Maintenance spare parts ....................................................................................................................
20
General ................................................................................................................................................. 21
Methods of destruction ...................................................................................................................... 22
Destruction of components ................................................................................................................ 23
.
....
APPENDIX REFERENCES ............................................................................................................................................................... e
iii
CHAPTER 1
INTRODUCTION
Section I. GENERAL
1. Scope
These instructions are published for the informa. tion and guidance of personnel to whom this equip,
ment is issued. They contain basic information on
the special tools, test equipment, and common supplies required by operating and maintenance personnel in a typical step-by-step dial central office.
They list and describe briefly the special tools, test
sets, installation materials, and maintenance spare
parts supplied initially by the manufacturer, as
well as the common tools, standard test sets, and
general maintenance materials obtained through
regular supply channels.
by the Army will be filled out and forwarded through channels to the Office of
the Chief Signal Officer, Washington 25,
D. C., when trouble occurs more often
than is normal, as determined by qualified
repair personnel.
(3) A F Form 54 (Unsatisfactory Report) for
equipment used by the Air Force will be
filled out and forwarded to Commanding
General, Air Materiel Command, WrightPatterson Air Force Base, Dayton, Ohio,
in accordance with A F Regulation 15-54.
b. Use other forms and records as authorized.
2. Forms and Records
3. References
a. The following forms are used in reporting
receipt, operation, and maintenance of the equipment :
(1) NME Form 6 (Report of Damaged or
Improper Shipment) for equipment used
by Army Field Forces and technical services will be filled out and forwarded in
accordance with SR 745--45-5 or AFR
71-4, when equipment is received in a
damaged condition or when it is necessary
to report unsatisfactory preservation,
packaging, packing, marking, loading, unloading, and handling of supplies.
(2) DA AGO Form 468 (Unsatisfactory
Equipment Report) for equipment used
This manual is one of a series of 15 technical
manuals dealing with the equipment which comprises a typical step-by-step dial central office. Detailed information on the operation, maintenance,
and installation of this cent~aloffice equipment is
given in the other manuals of the series, listed in
the appendix. The appendix also contains a list
of current references, including supply catalogs,
technical manuals, packaging specifications, and
other available publications. I n addition, it lists
the forms required for use by using personnel in
the performance of prescribed operations. General
maintenance procedures and routines involving the
use of tools, test sets, and supplies described in this
manual are covered in TM 11-2103.
Section II.
DESCRIPTION AND DATA OF TEST EQUIPMENT
4. General
M o d step-by-step dial central offices are equipped
with a type 1 wire chief's test desk, which provides
centralized testing facilities for the maintenance of
both the central office and outside plant equipment,
and with several portable test sets for routine testing
of the central office switching equipmelit. These test
sets include a connector routine test set, a currentflow test set, and a test handset. Other test equip-
ment, sometimes required by dial central office
maintenance men or by outside plant repairmen,
can be'obtained through regular supply channels.
5. Type 1 Test Desk
The wire chief's test desk is the major center for
fault location and equipment tests in a typical stepby-step dial central office. Although additional test
sets. are used in the central office, most basic tests
1
can be performed from the test desk. Detailed
information and operating instructions on the type
1 test desk are given in TM 11-2110. Other tools
and test equipment used in dial central office maintenance are described in TR!I 11-372 and TIT 11-487.
The following test equipment components and circuits comprise the type 1test desk:
a. VOLT-OHM-MILLIAMMETER.
This multirange
meter has ranges of 0-15, 0-150, and 0-600 volts,
0-150 and 0-600 milliamperes, and 0-5,000, 0-50,000 and 0-500,000 ohms. I t is used primarily as a
continuity tester in determining the nature and
extent of electrical faults within the central office.
b. WHEATSTONE
BRIDGE.The Wheatstone bridge
is a precision resistance bridge which has a range
of 1ohm to 10 megohms. I t is used to make generalpurpose resistance measurements and to detect cable
faults in the outside plant equipment.
c. DIALSPEED
AND PULSE
RATIOTESTSET. This
test set measures dial speeds in pulses per second
and the percent make (pulse ratio) of dial pulse
spring contacts..
d. HOWLERAND INSULATION
BREAK-DOWN
TEST
CIRCUIT.The howler circuit provides a loud tone to
signal a telephone user when a handset is left off
the cradle and no call is in progress. The insulation break-down test circuit is used to test telephone
lines for break-down of insulation upon the application of a high potential.
e. TEST CORDAND TEST TRUNKCIRCUITS.The
test cord cir&its connect the test desk to the desired
test trunks. The test trunks circuits permit direct
connection for test purposes from the test desk to
any telephone line of the central office.
f. NIGHTALARMCIRCUIT.The night alarm circuit provides an audible alarm, or buzzer sound, on
incoming calls during night service or periods when
the test desk is unattended.
y. IN-CALLAND OUT-CALL
WIRE CIRCUITS.These
call-wire circuits permit intereommuizication between two or more test desks or between a test desk
and an illformation center, repair center, or switchboard.
theory of operation and operating instructions for
the connector routine test set are covered in TM
11-2113. This test set checks the following functions of connectors and reverting-call switches :
(1) Connector f u n c t i o n s tested. The connector
routine test set tests the following functions of connectors :
(a) Vertical and rotary stepping from pulses
over a high-resistance loop.
( b ) Vertical and rotary stepping from pulses
over a loop having low leakage resistance.
(c) Returning busy tone when stepped to a
busy line.
( d ) Extension of ringing current to the
called line and ring-back tone to the
calling line when the wipers are stepped
to an idle line or trunk.
(e) Completion of the talking circuit over
an idle line or trunk.
6. Test Sets Supplied by the ~anufclcturer
a. CONNECTOR
ROUTINETESTSET. The connector
routine test set (fig. 1) is used for the routine testing of the regular conneetors, PBX (Private Branch
Exchange) connectors, and revei-ting-call switches
in a typical step-by-step dial central office. Detailed
TM 2111-1
Figure 1. C o n n e c t o r routine t e s t set.
flow test set. This test he1 rucAilqnresthc
clcctriccrl opo.ntc value, or specified minimum cnrrcnt through the relay windings
to oprrnte the relay. a n d the elcclra'cal
?to,ioprrntc ralur. or the masiinmn current,
flow throng11 the windings witllont operating the relay. I t consists of sets of adjnstable rrsistanrc~bnlllis, n millinmmetcr, and
siiit;~l)lcopcwting controls. The resistancc
b;inlrs arc arljnsted mitil tllc nlarginal
opclrrrfcand ~ i o t t o l ~ w n f c
current-flow values
arc intlicatcd on the milliammctcr. in accorclauc~cwit11 circuit rcqni~.emenl tal~lcs
or ~ ~ c l i l y
atlji1stmc1nt sllcets prcpnrccl by the
mannfi~ctnrcr. The operate anc1 nonopcrate test. pctnformrd n-it11 Ihc cnrrcl~t-flow
test sct, givc.s :111 accuriltc indicatinl~.of
t hc opol~ating (~fficiency of relays. IVhcn
rcatl.justing a rcnlay, rising the cnrrent-flow
t-cst s ~ t .thv r(bl;ly contirct sprir1g.q arc ten-
( J ) Release U I I I I V
ronncctor u-ht~nthe last
(calling or callrcl) party llangs up.
( 2 ) Rrt*~rfing-en11
szc.ifelr f 1oictiolt.s t c s f f d .The
following f ~ u ~ c t i o n sof reverting-c a l 1
switches are chedrccl 1)y tlic coniiector routine test set :
( ( 1 ) Pnlsinq over a loop ~-11icl1has a rcsistnnce hieher thiln normal to seize n rcvcrting-call switvh.
( b ) Revertirlg-(*a11riiigillr o w r n line which
lias a higher than normal rec;istaiice.
( c ) Ringinn cut-off wllcn callccl party answers.
((7) Rcletlse when the last p i ~ r t \ -hillin.; 11p.
b. C U R R E S T - F I ,
TEST
~ ~ 'SET.
( 1 ) dl)plicrrtiorr. Rela\-s iisctl in step-by-step
dial rcntral officck c.clnil)mcnt are tcstccl
nil adjustctl in accortiancc n-it11 electrical
l)erf'ornii~ncc~
rtlcluirrmcntq 1)y il c ~ i r r c n t T
T
-
,'
SW LOCK
4ON-OPERA1
jW ROW
T.
RMS.
X EXT
RMS.
T TEST
RMS.
t H 0 9 T PUSH
IUTTON
RESISTANCIZ
RANGE SW
N OPR - C )PA
RELAY T EST SW
'
B A T T CUT-OI 'F
METER
REVERS ING SW
sW
\
st
MI
"' LItL-0
-
F i : ~ r t ~ ,9.
c ('ro.r/ 111-flail. t r s t
t.
sioned and adjusted until the relay meets
the operate and nonoperate current-flow
requirements. This operation is sometimes
called mnrgining.
(2) T!ypical current-flow fesf set. A typical
current-flow test set used in many stepby-step dial central offices is illustrated in
figure 2. The milliammeter of this test set
corers current-flow ranges of 0-30, 0-150,
and 0-750 milliamperes; the resistance
banks are adjustable in h h m steps from
5 to 22,215 ohms. An auxiliary 20,000-ohm
resistor increases tlie resistance range to
42,215 ohms. Provision is made also for
connecting esternal resistors of any dcsired resistance value in series with the
resistance banks. Lei-er switches (keys)
control the resistance value and milliammeter ranges. Special test cords for connecting the test set to the contact springs
of relays are usually included with the
cnrrent-flow test set. TJI 11-2112 describes the operation and nse of the current-flow test set.
S o t c . Standard Current-flow Test Set 1-181
(par. 8 b ( 5 ) ), wliicl~can be obtained through
regular supply el~m~ncls,
may Ile used instead
of tlie current-flow t c s t set furnished b y the
mmluf acturer.
-.--.- - -
7
c. STEPPISG-SWITCH
TESTSET. This test set is
an automatic interrupter which generates pulses
for use in testing the vertical stepping of selectors,
tlie vertical and rotary stepping of connectors, and
the action of pulse repeaters, all under simillated
loop resistance and leakage conditions. The stepping-switch test set (fig. 3) is also called imp~rlse
testing machine, varying ntacltine, interrupter mac l ~ i n e ,dial pulse generator, and test pulse nlackine
in the manufacturer's literature, specificat,ions, and
drawings. I n relatively large step-by-step dial central oficcs, this test is used widely for fast and
accnrnte routine testing on selector and connector
s~ritcl~
shelves, thereby eliminating the necessity for
dialing test digits for each switch tested. This saves
time mlien larqc numbers of switches must be tested,
siilce three digits are required for testing 200-point
connectors with test sets, such as the test handset
(par. 'in), ~vhichrequire dialing to produce test
pulses. I n smaller step-by-step dial central offices,
ho~vevcr,this test set generally is not used for routine testing. I n this case, the connector routine test
set is preferred by repairmen for checking the stepping action of connectors while the test handset is
preferred for checking the stepping action of selectors. Use of the stepping-switch test set in smaller
offices is limited to the repair or readjustment of the
-
- -.
-
-- -.--m
--*--"
EXTENSION
S W ITCHBOX
.
SlON
Figtire 3. Stepping-stc.itclr test set.
AT.
CABLE
TI
12114-2
DIAL
AND
(RECEIVER
HOUSING
Figure 4. Test handset.
stepping mechanism of the selectors and connectors.
TM 11-2114 describes the application, functioning,
and operating procedure of the stepping-switch
test set.
7. Other Test Equipment Supplied by the
Manufacturer
a. TESTHANDSET.
The test handset (fig. 4) is a
test telephone having a transmitter at one end and
a receiver and dial mounted back to back at the
other end. I t is used for dialing, monitoring, and
talking tests on the switching equipment of a typical step-by-step dial central ofice. There are two
push switches (push buttons), marked C and R on
the handle of the handset, which are located just
below the dial and receiver. The test handset is also
equipped with a test cord and special test plug which
mates with the test jack terminals of the switch to
be tested.
b. TEST LAMP. A small test lamp (fig. 5) for
continuity testing is provided with the step-by-step
dial central office maintenance tools supplied by the
CLIP FOR
TEST
CONNECTION
OR
#
BV
SWBD
LAMP
Figure 5. Test lamp.
*il
manufacturer. The unit consists of a lampholder, a
test prod, and a 6-foot test cord with a special clip
for connecting to the relay contact springs: A 48volt telephone switchboard-type lamp is ordinarily
used in this test unit. The lamp filament resistance,
when cold, is 185 ohms and, when hot, varies between 1,260 and 1,500 ohms.
8. Signal Corps Standard Test Equipment
Additional items of test equipment, which are not
supplied by the manufacturer, may sometimes be
required in the maintenance and repair of step-bystep dial central ofiice equipment or the outside
plant equipment. For additional information on
this test equipment, which is usually obtained
through regular supply channels, refer to TM 11487 and TAI 11-372. The standard test sets which
are obtainable from regular supply channels and
which are used most commonly in the maintenance
of the equipment of a typical step-by-step dial central office are listed below.
a. TESTSET TS-19O/U. This is a high-resistance
test receiver, having a headband and a three-conductor test cord. The test receiver has a 1,000-ohm impedance. An external 50,000-ohm resistor normally is connected in series with the receiver. A switch
cuts out this resistor when it is not required. The
test set is equipped with a three-conductor test cord,
an alligator clip, and a test prod for probing in a
circuit. Test Set TS-19O/U is used for making
trouble location tests, for continuity testing, and
for checking circuits for the presence of negative
battery or ground. The 50,000-ohm resistor protects
the user against loud clicks when testing for potentials in circuits, and provides a high-impedance
monitoring circuit to bridge across circuits without
affecting performance. The test receiver may be
used when identifying cable pairs, since its high
resistance will not operate or restore any relays in
the equipment. For details concerning the use of
Test Set TS-19O/U in the maintenance of equipment in a typical step-by-step dial central office,
refer to TM 11-2103.
b. PORTABLE
TEST SETS. The following pontable
test sets, when available, are used frequently in the
maintenance and repair of step-by-step dial central
office equipment :
(1) Voltohmwzeter 1-166. This test set is a
portable self-contained multirange voltohmmeter for measuring a-c and d-c voltages and resistances. Operating instruc-
tions for this instrument are given in TM
11-2613.
(2) Test Set TS-26/il'SM. This instrument is
a portable, fault-locating test set, which
contains a 45-volt test battery. It measures d-c voltages and resistances. Operating instructions for Test Set TS-26/TSM
are contained in TM 11-2017.
(3) Test Set TS-27/TSM. This test set is a
form of Wheatstone bridge used for line
tests, but is equipped, in addition, with a
vacuum-tube oscillator which supplies 20cycle current for capacitance tests and
fault location. Operating instructions for
Test Set TS-27/TSM are outlined in TM
11-2057.
(4) Test Set 1-49. This instrument is a portable, self-contained Wheatstone-bridge test
set, especially adapted for locating faults
in communication circuits. I t differs
slightly from the Wheatstone bridge which
is part of the type 1test desk used in nlany
step-by-step dial central offices. Refer to
TM 11-2019 for operating instructions and
fault-locating procedures for Test Set I49.
( 5 ) Test Set I-48-B.
This instrument is a
portable insulation-resistance test set with
a range from 0 to 1,000 megohms. Operating instructions for Test Set I-48-B are
given in TM 11-2050.
(6) Test Sets I-61-A, I-61-B, nmd I-614.
These test sets are portable, self-contained,
transmission-measuring units, incorporating an audio oscillator for sending, an
amplifier for receiving, and a power-level
meter. Test Sets I-61-B and I-61-C also
include a local-battery Telephone EE-8-B.
Operating instructions for these test sets
are found i11 TM 11-346.
(7) Cable fault-locating equipment. Refer to
TM 11-372 and TM 11-487 for information
on Test Set 1-51, WECo Test Set 62-A,
WECo Test Handset 1011-BW, Test Set
TS-420/U, and other equipment used in
the testing of outside plant equipment.
(8) Test Set 1-181. This portable, standard
current-flow test set is used in testing and
adjusting relays of step-by-step dial central office switching equipment, in accordance with the manufacturer's electrical
~
specifications. Its continuously variable
resistance range makes this test set especially suited for precision testing and adjusting of relays, since the current-flow
test set furnished by the manufacturer
(par. 6b) has its resistance range in 5-ohm
steps. Two control knobs in each resistance
path of this standard test set provide a
coarse setting and a fine adjustment which
permit accurate measurement of the marginal current-flow requirements. For details concerning the operation and use of
Test Set 1-181, refer to TM 11-2036. Test
cords and connectiiig tools, as listed in TM
11-2036, are required for use with Test
Set 1-181, but are not provided as part of
the test set.
( 9 ) l'est Xets 1-242 and I-142A. These test
sets incorporate a number of relatively independent test circuits for measuring the
electrical characteristics of step-by-step
dial central office equipment. Detailed
information on Test Sets 1-142 and I142A is contained in TM 11-2062. It includes the following test circuits:
( a ) Measzcring circuit. A variable-range,
vacuum-tube type volume indicator is
used for-measuring the electrical output
of telephone transmitters or receivers.
( b ) Capacitor test circuit. A relasationtype oscillator is used to check the leakage resistance of capacitors.
( c j Generator tesl circuit. This test circuit
is nsed for checking the electrical rating
of generators used in central offices.
( d ) Ringer test circuit. This circuit consists of a hand-operated generator and
resistors arranged to supply minimum
operating currents of approximately 162/3 cps (cycles per second) to ringers of
three different impedances.
( e ) Znsz~lationresistance test circuit: This
test circuit 'measures resistances of 1
megohm or less.
( f ) Dial test circuit. This test circuit measures the speed of the dial pulse spring
contacts and the percentage of the total
pulse period during which the dial pulse
spring contacts are closed (pulse ratio,
or percent make, of the dial pulse spring
contacts).
( g ) Continuity test circuit. A buzzer and
lamp are provided in this test circuit for
making point-to-point tests for electrical
continuity.
( h ) Instrument test circuits. These circuits
are provided for testing the efficiency
of common- and local-battery telephones.
9. Dial Speed and Pulse Ratio Test Set
A portable dial speed and pulse ratio test set
(fig. 6) is used by installation and maintenance men
to check the speed and pulse ratio, or perceiit make
(ratio of the tiMe the dial pulse spring coiltacts are
closed to the length of the pulse period), of dials of
telephone sets. This test set usually is included
with the installation tools which are furnished by
Figure 6. Dial speed a n d pulse ratio t e s t set.
7
the manufacturer with the dial central office equipment. I t may be used to make dial tests at the point
of installation, but it is more adaptable for use at
test and repair benches. The speed of dials must be
within certain limits to m u r e proper functioning
of stepping switches which are actuated by dial
pulses. A dial speed of 10 pulses per second is considered ideal, while extreme test limits for dial
speeds are 8 and 14 pulses per second. Normal percent make, or pulse ratio, of dial pulse spring contacts is approximately 38% per cent. The test set
also can be used to make rapid approximations of
the pulse ratio of a short series of dial pulses (par.
17c (3) ) . A milliammeter on the front panel of the
test set registers both dial speeds and percent make
of a series of pulses. This milliammeter has two
scales, one for dial speeds, calibrated from 0 to 15
pulses per second and the other for pulse ratios,
calibrated from 0 to 100 percent make. The dial
speed and pulse ratio test set (fig. 6) is set normally
for percent make tests. To use the test set as a dial
speed indicator, SPEED-SET FULL SCALE
switch must be operated to the SPEED position.
10. Type 31 Portable Dial Speed Test Set
(fig. 7)
a. GENERAL. For efficient operation of the
switching equipment in a step-by-step dial central
office, the speed of rotation of telephone dials must
be kept at approximately 10 pukes per second.
Therefore, test equipment for the accurate determination of dial speeds is required by dial central
office maintenance men. Thus, wire chief's test
desks in newer central offices are equipped with dial
speed and pulse ratio testing equipment which can
Figure 7 . Type 31 dial speed test set.
be used both as a dial speed indicator and a dial
pulse ratio (percent make) test set. A portable dial
speed and pulse ratio test set (par. 9) is also furnished initially by the manufacturer with the newer
dial central office equipment. The type 31 portable
dial speed test set (fig. 7) is used in some older central offices. The components of this test set are incorporated in older models of the type 1 test desk,
used in some earlier step-by-step dial central ofices.
It consists of two relays, a stepping magnet, a circuit-breaker, a single-throw, locking-type lever
switch, and a spring-driven timing mechanism which
moves the pointer from left t o right on the indicator
scale. The test set is mounted on a laminated panel
which is faced and backed with bakelite. The unit
is mounted in a wooden carrying case by means of
four wood screws. The dial speed indicator, the
lever switch, and four binding posts (marked T, R,
+GND and -48) are mounted on the front of this
panel. The two relays, equipped with individual
dust covers, and a 3-ampere, cartridge-type fuse are
mounted on the rear of this panel. The type 31
dial speed test set operates from an external 48-volt
battery supply, connected to the two lower binding posts (+GND and -48) on the front of the
panel.
b. APPLICATION.
Type 31 dial speed test set is
used as a portable testing unit for repairing or ad-
justing dial mechanism of dial telephone sets. I t is
furnished as part of the installation tools provided
by the manufacturer. When used at a repair or
testing bench, the test set is useful in making dial
speed tests on dial telephone sets prior to installation. I t is used by installer-repairmen to check and
test dials. I t may be used also for completing dial
tests at the attendant's switchboard if the installation of the test desk has not been completed.
1 1. Buzzer Test Set
A portable buzzer test set (fig. 8 ) operated by two
l$4-volt, dry-cell batteries (BA-23), usually is included with the installation tools which are furnished by the manufacturer. The buzzer and the
batteries are contained in a wooden case. The buzzer
test set is used during cabling and wiring of the
step-by-step dial central office equipment to identify
cable conductors and t o test and verify the wiring
after the installation is completed. A buzzer test
set similar to that illustrated in figure 8 is a necessary item in step-by-step dial central office maintenance. If not available, buzzer test sets can be
constructed locally. The buzzer test set and a
switchboard plug are used in making continuity
tests on switchboard multiple cables during installation.
Figure 8. Buzzer test set.
12. Test Stand
A special test stand (fig. 9 ) is supplied with the
step-by-step central office maintenance tools furnished by the manufacturer. The test stand is
used to support two-motion stepping switches when
removed from the shelf positions for adjustment or
repair. A 24-terminal test jack is included on the
test stand for making connections to negative battery and ground. This permits operating tests to
be made on stepping switches while mounted on
the test stind. Bayonet pins i n the upright members of the test stand support switching units which
have a large mounting base. Smaller mounting
bases are supported on the test stand by screws
inserted in tapped holes in the upright members.
F i p w 9. Test s t c ~ t d .
CHAPTER 2
OPERATING INSTRUCTIONS AND THEORY OF OPERATION FOR TEST EQUIPMENT
13. Test Handset (figs. 4 and 10)
(j) After testing all idle linefinders in the
B group, momentarily operate the group
relay busy switch of the B group. Then
restore the B group busy switch to transfer back to the A group of linefinders.
Make sure that the linefinder equipment
transfers both ways, from the A to the B
group and then back to the A gronp.
(2) Selector trunk test. Test selectors in
groups of ten with the test handset as follows :
+
a. OPERATING
INSTRUCTIONS.
(1) Linefinder operation test. Perform routine testing of linefinders with the test
handset as follows :
(a) Plug the handset test cord into the two
bottom springs of the test jack associated
with the A group of linefinders. Note
that one of the linefinders in the A group
steps its wipers to the contacts on its
banks which correspoild to the test line
(No. 29).
(b) Listen to the test handset receiver for
dial tone.
(c) On hearing dial tone, hold push switch
R operated and dial any digit corresponding to a vacant, or unused, selector
bank level, as shown on the central office
cabling diagram, or on the selector
terminal assembly drawing. Listen for
busy tone. Release push switch R.
(d) Operate push switch C on the handle of
the test handset. The linefinder which
mas seized previously ( ( a ) above) releases upon operation of switch C.
(e) Release push switch C on the test handset handle. The next idle linefinder
should step its wipers u p to the contacts
on its banks which correspond to the test
line (No. 29).
(f) To test all other idle linefinders in the A
group, repeat steps described in (a)
through ( e ) above.
(g) When all idle linefinders in group A
have been tested, operate the group relay busy lever switch (key) of the A
group.
( h ) Restore the group relay busy switch of
the linefinders A group.
(i) Make a similar operation test of each idle
linefinder in the B group of linefinders
from the B gronp test jack by repeating steps described in ( a ) through ( f )
above.
( a ) Insert the handset test plug in the two
top selector test jack springs.
( 6 ) Hold push switch R operated and dial
any test digit. Observe whether the
selector steps its wipers up to the dialed
level and around to the contacts of the
first idle trunk.
(c) Rapidly open and close the VON (vertical off-normal) springs and note that
the selector shaft steps its wipers around
to each trunk on the dialed level. If an
open trunk is encountered, the shaft will
fail to rotate.
( d ) Listen for busy tone each time the selector wipers reach the eleventh rotary step.
(e) Test each selector bank level in a similar
manner. On vacant levels, the selector
wipers should rotate to the eleventh rotary step and return busy tone.
( f ) Test all trunks on all selector levels,
using a diffcrenb group each time the
test is made, so that ultimately all groups
will be tested.
( 3 ) Xelector cut-in and release test. Perform
this selector test using the test handset as
follows :
( a ) Plug the handset test cord into the two
top test jack springs of a selector.
( b ) Holding push switch R of the test handset operated, dial a digit which will
cause the selector to step its wipers up
to the bank level being tested.
(c) Observe that the selector wipers cut in
properly and rotate to the first idle trunk
on the dialed bank level.
(d) Dial the digit 1 to insure that the line
switching relay of the selector has operated properly. Failure of the line
switching relay will be indicated by a
vertical kick of the shaft when the second digit is dialed. Release test handset
push switch R.
(e) Observe that the selector releases properly upon disconnection.
(f), Test a different bank level at each inspection to insure that the selector
wipers will beqtested ultimately on all
bank 1e;els.
(4) Two-way repeater trunk test. Test each
two-way repeater with the test handset
as follows :
(a) Plug the test handset into the top and
bottom test jacks of the repeater and
operate push switch C on the handset.
Monitor the trunk to determine whether
the trunk is idle.
(6) Holding push switch R of the handset
operated, dial the reverse battery number in the distant central office and listen
.for a click in the handset receiver.
(c) When the reverse battery click is heard,
proceed to the next repeater. Test repeaters to manual central offices by dialing the operator.
(d) Release push switch R and operate push
switch C of the test handset. This
permits the trunk equipment to release.
(e) Busy out any repeater which fails to
meet the test outlined in the steps described in (a) through (d) above, and
notify the distant central office of the
trunk in trouble.
(f) Make a note of all busy trunks and test
each one when it becomes idle.
b. THEORY
OF OPERATION.The test handset circuit (6g. 10) consists of a telephone transmitter,
receiver, dial, an induction coil, a 0.43-microfarad
capacitor, a 1,200-ohm resistor, and push switches
C and R. Plugging the test handset into the test
jack of a stepping switch closes the loop to that
switch, making the switch busy to other calls and
preparing it for dialing or talking tests. Push
switch C, when in the unoperated (closed-contact)
position, normally short-circuits the 0.43-microfarad
capacitor. When held operated, however, push
switch C opens the transmitter circuit and forms a
listening circuit through the capacitor and receiver
in series. This permits the testman to monitor on
busy equipment. To talk with a called party on the
loop, the testman releases push switch C, thereby
closing the transmitter circuit again. Similarly,
push switch R normally short-circuits the 1,200-ohm
resistance. When the testman holds push switch R
operated, the short circuit is removed and the resistance is connected in series with the loop. This
provides a standard 1,200-ohm test loop over which
dial pulses from the test handset dial may be sent
to test the stepping action of the stepping switch
under test. The 1,200-ohm resistance in series with
the loop simulates the extreme limit of loop resistance for test purposes. The test handset may be
adapted for other tests by disconnecting the special
plug from the test cord, and using test clips, terminal lugs, or standard telephone plugs, which permit
connection of the handset to other equipment.
XMTR
TM2103-II
Figure 10. Test handset, schematic diagram.
14. Test Lamp (fig. 5 )
a. OPERATINGINSTRUCTIONS.
Make continuity
tests with the test lamp on relay circuits of the stepby-step dial central office switching equipment as
follows :
(1) To test the continuity of a relay circuit
which is connected to ground, but not to
negative battery, connect the test clip of
the test lamp to a negative-battery source
and make point-to-point exploratory tests
with the test prod. Lighting of the test
lamp will indicate the presence of ground
in the circuit.
(2) When the relay circuit under test is connected to negative battery, but not to
ground, connect the test clip to ground
and make continuity tests with the test
prod. The presence of negative battery in
the circuit is indicated by lighting of the
test lamp.
(3) If the relay circuit is not connected to
negative battery, or ground, connect the
test clip in series with the central office
battery and perform continuity tests with
the test prod.
'
( 3 ) To calibrate the test set initially for dial
speed tests, operate the SPEED-SET
FULL SCALE lever switch to the SPEED
position (fig. 6) and adjust the SET FULL
SCALE control knob until the meter registers an average dial speed reading of 10
pulses per second.
(4) Dial, or instruct the telephone user or the
repairmen at the distant dial telephone set
to dial, the digit zero ( 0 ) .
(5) Read the speed of the dial under test directly on the meter scale (fig. 6 ) . A meter
reading of 8 pulses per second or lower
indicates a slow dial speed; a meter reading of 14 pulses per second or higher indicates a fast dial speed. When readjusting
dials, try to obtain a dial speed reading
of 9 to 11pulses per second.
b. THEORY
OF OPERATION.
The test lamp circuit,
used in point-to-point localization tests, consists of
a lamp with a thin metal probe, or test prod, at one
end, and a length of flexible cable terminating in a
test clip at the other end. The test clip is connected .
to known ground or negative battery, while the test
prod is used in tracing circuits point by point. The
presence of ground or negative battery in a given
b. PERCENT
MAKETEST. TOperform pulse ratio,
circuit under test is shown by the lighting of the
or percent make, tests with the dial speed and pulse
test lamp. When the test prod touches each point
ratio test set, proceed as follows:
in a circuit connected to ground, it completes the
lamp circuit from ground through the lamp to nega(1) To calibrate the test set initially for pertive battery thus lighting the lamp. Similarly, negcent make tests, operate the SPEED-SET
ative battery can be traced from point to point in
FULL SCALE switch temporarily to the
any circuit. I n each case, a continuous circuit is
SPEED position and adjust the SET
required to light the test lamp. Failure of the
FULL SCALE control knob for full-scale
lamp to light indicates an open circuit.
deflection of the meter pointer.
15. Dial Speed and Pulse Ratio Test Set
(figs. 6 and 11)
a. OPERATINGINSTRUCTIONS
FOR DIAL SPEED
TESTS. TO use the dial speed and pulse ratio test
set as a dial speed indicator, proceed as follows:
(1) Connect the dial telephone set being tested
to the P I and G binding posts of the test
set (fig. 6). Connect a jumper wire between the negative (-)
and P2 binding
posts of the test set.
(2) Connect the 48-volt battery supply of the
central office to the positive (+) and negative (-) binding posts of the test set (fig.
6 and A in fig. 11). When using the test
set at an outside telephone set which has
no battery supply available, connect the
telephone line to the positive and negative
binding posts, and request the central office testman to*supply negative battery
over the line. If the test set is being used
at the central office for dial tests over the
telephone lines, connect the line which is
being tested to the P1 and G binding posts.
(2) Hold. the PRESET READING lever
switch operated temporarily, and adjust
the PRESET READING control knob
until the meter pointer reaches full-scale
deflection.
(3) Release the PRESET READING lever
switch.
(4) Dial, or request the telephone user or the
repairman at the distant dial telephone
set to dial, the digit zero. The